Type L Extension Cable Chromel / Copper Material Silicon Insulation

Model NO.: K-HP-1113
Material Shape: Round Wire
Range of Application: Machinery,Thermocouple,Electricity
Certification: ISO9001, ANSI
Brand: Ohmalloy
Trademark: OHMALLOY
Transport Package: 100m/Spool, 305m/Spool, 1000FT/Spool, 1000m/Spool
Specification: AWG 20 AWG 18 AWG 8
Origin: China
Model NO.: K-HP-1113
Material Shape: Round Wire
Range of Application: Machinery,Thermocouple,Electricity
Certification: ISO9001, ANSI
Brand: Ohmalloy
Trademark: OHMALLOY
Transport Package: 100m/Spool, 305m/Spool, 1000FT/Spool, 1000m/Spool
Specification: AWG 20 AWG 18 AWG 8
Origin: China

Type L Extension Cable Chromel / Copper Material Silicon Insulation

 

Specifications


1.Style:Extension Wire
2.Thermocouple copper wire
Thermocouple copper wire Classification
1. Thermocouple level (high temperature level). This type of thermocouple wire is mainly suitable for thermocouple type K, J, E, T, N and L and other high temperature detection instrument, temperature sensor, etc.
2. Compensating wire level (low temperature level). This type of thermocouple wire is mainly suitable for compensating cable and extension wire of various thermocouples of type S, R, B, K, E, J, T, N and L, heating cable, control cable and so on.

Thermocouple variety and index


Thermocouple Variety and Index

Variety

Type

Measurement Range(°C)

NiCr-NiSi

K

-200-1300

NiCr-CuNi

E

-200-900

Fe-CuNi

J

-40-750

Cu-CuNi

T

-200-350

NiCrSi-NiSi

N

-200-1300

NiCr-AuFe0.07

NiCr-AuFe0.07

-270-0

 

3 . Dimensions and Tolerance of Fiberglass Insulated Thermocouple Wire

Dimensions / Tolerance mm ) : 4.0+-0.25


Color code & initial calibration tolerances for thermocouple wire:

Thermocouple Type ANSI Color Code Initial Calibration Tolerances
Wire Alloys Calibration +/-
Conductor
Jacket Temperature Range Standard
Limits
Special
Limits
Iron(+) vs.
Constantan(-)
J White/Red Brown 0°C to +285°C
285°C to +750°C
±2.2°C
± .75%
±1.1°C
± .4%
CHROMEL(+) vs.
ALUMEL(-)
K Yellow/Red Brown -200°C to -110°C
-110°C to 0°C
0°C to +285°C
285°C to +1250°C
± 2%
±2.2°C
±2.2°C
± .75%
±1.1°C
± .4%
Copper(+) vs.
Constantan(-)
T Blue/Red Brown -200°C to -65°C
-65°C to +130°C
130°C to +350°C
± 1.5%
±1°C
± .75%
± .8%
± .5°C
± .4%
CHROMEL(+) vs.
Constantan(-)
E Purple/Red Brown -200°C to -170°C
-170°C to +250°C
250°C to +340°C
340°C+900°C
± 1%
±1.7°C
±1.7°C
± .5%
±1°C
±1°C
± .4%
± .4%


Color Code & Initial Calibration Tolerance for Extension Wire:

Extension type ANSI Color Code Initial Calibration Tolerances
Wire Alloys Calibration +/-
Conductor
Jacket Temperature Range Standard
Limits
Special
Limits
Iron (+) vs. Constantan(-) JX White/Red Black 0°C to +200°C ±2.2°C ±1.1°C
CHROMEL (+) vs. ALUMEL (-) KX Yellow/Red Yellow 0°C to +200°C ±2.2°C ±1.1°C
Copper(+) vs. Constantan(-) TX Blue/Red Blue -60°C to +100°C ±1.1°C ± .5°C
CHROMEL(+) vs. Constantan(-) EX Purple/Red Purple 0°C to +200°C ±1.7°C ±1.1°C


PVC-PVC Physical Properties:

Characteristics Insulation Jacket
Abrasion Resistance Good Good
Cut Through Resistance Good Good
Moisture Resistance Excellent Excellent
Solder Iron Resistance Poor Poor
Service Temperature

105ºC continuous

150ºC single

105ºC continuous

150ºC single

Flame Test Self-extinguishing Self-extinguishing

Type L Extension Cable Chromel / Copper Material Silicon Insulation

 

Type L Extension Cable Chromel / Copper Material Silicon Insulation

 

Specifications


1.Style:Extension Wire
2.Thermocouple copper wire
Thermocouple copper wire Classification
1. Thermocouple level (high temperature level). This type of thermocouple wire is mainly suitable for thermocouple type K, J, E, T, N and L and other high temperature detection instrument, temperature sensor, etc.
2. Compensating wire level (low temperature level). This type of thermocouple wire is mainly suitable for compensating cable and extension wire of various thermocouples of type S, R, B, K, E, J, T, N and L, heating cable, control cable and so on.

Thermocouple variety and index


Thermocouple Variety and Index

Variety

Type

Measurement Range(°C)

NiCr-NiSi

K

-200-1300

NiCr-CuNi

E

-200-900

Fe-CuNi

J

-40-750

Cu-CuNi

T

-200-350

NiCrSi-NiSi

N

-200-1300

NiCr-AuFe0.07

NiCr-AuFe0.07

-270-0

 

3 . Dimensions and Tolerance of Fiberglass Insulated Thermocouple Wire

Dimensions / Tolerance mm ) : 4.0+-0.25


Color code & initial calibration tolerances for thermocouple wire:

Thermocouple Type ANSI Color Code Initial Calibration Tolerances
Wire Alloys Calibration +/-
Conductor
Jacket Temperature Range Standard
Limits
Special
Limits
Iron(+) vs.
Constantan(-)
J White/Red Brown 0°C to +285°C
285°C to +750°C
±2.2°C
± .75%
±1.1°C
± .4%
CHROMEL(+) vs.
ALUMEL(-)
K Yellow/Red Brown -200°C to -110°C
-110°C to 0°C
0°C to +285°C
285°C to +1250°C
± 2%
±2.2°C
±2.2°C
± .75%
±1.1°C
± .4%
Copper(+) vs.
Constantan(-)
T Blue/Red Brown -200°C to -65°C
-65°C to +130°C
130°C to +350°C
± 1.5%
±1°C
± .75%
± .8%
± .5°C
± .4%
CHROMEL(+) vs.
Constantan(-)
E Purple/Red Brown -200°C to -170°C
-170°C to +250°C
250°C to +340°C
340°C+900°C
± 1%
±1.7°C
±1.7°C
± .5%
±1°C
±1°C
± .4%
± .4%


Color Code & Initial Calibration Tolerance for Extension Wire:

Extension type ANSI Color Code Initial Calibration Tolerances
Wire Alloys Calibration +/-
Conductor
Jacket Temperature Range Standard
Limits
Special
Limits
Iron (+) vs. Constantan(-) JX White/Red Black 0°C to +200°C ±2.2°C ±1.1°C
CHROMEL (+) vs. ALUMEL (-) KX Yellow/Red Yellow 0°C to +200°C ±2.2°C ±1.1°C
Copper(+) vs. Constantan(-) TX Blue/Red Blue -60°C to +100°C ±1.1°C ± .5°C
CHROMEL(+) vs. Constantan(-) EX Purple/Red Purple 0°C to +200°C ±1.7°C ±1.1°C


PVC-PVC Physical Properties:

Characteristics Insulation Jacket
Abrasion Resistance Good Good
Cut Through Resistance Good Good
Moisture Resistance Excellent Excellent
Solder Iron Resistance Poor Poor
Service Temperature

105ºC continuous

150ºC single

105ºC continuous

150ºC single

Flame Test Self-extinguishing Self-extinguishing

Type L Extension Cable Chromel / Copper Material Silicon Insulation

 

Quick Turn PCB


We always believe that The time is a money! The efficiency is a life! The trustworthiness is forever!  

The fastest lead time is 48 hours, meanwhile quality is very good.

The various option of lead time can be offered as long as you need quick turn PCB.


How do we make efforts to fulfill our promise?

  • ERP system assures rapid quoting, order entry, engineering, tooling, production, testing, and shipping.
  • 24 hours online. Three shifts.
  • All in-house production of standard PCB processing.
  • Enough and various materials are stored well.
  • Strict control of production time and product quality.

If you demand quick turn PCB Board, just tell us your idea, we will make it!

Fast Turn PCB
 Quick Turn PCB

Quick Turn PCB

Quick Turn PCB,PCB Sample,Proto PCB,Fast PCB Prototype

JingHongYi PCB (HK) Co., Limited , http://www.pcbjhy.com